Server Room Cooling Down? Portable Aircon Rental in Singapore
When the CRAC unit fails, the racks do not wait. Portable air conditioners, delivered and set up so the cold air is on the rack fronts and the hot air is out of the room — while your contractor fixes the real thing.
★★★★★5.0 · 403 client reviews · Since 1985 · Delivered · Installed · Tested
Cold that turns up ready
Cold on the rack fronts
We aim the units at the intake side of the racks, not at the room in general — the air has to reach the equipment that is heating up.
Hot air leaves the room
Every unit runs an exhaust hose out through the door or a window opening. Cooling a sealed room without ducting the heat out just moves the problem around.
Sized for rack heat, not floor area
A server room is not an ordinary room. Racks pour heat in continuously, so we work to roughly a twentieth of the manufacturer’s floor rating — which is why a rack row usually needs two units, not one.
Nothing drilled, nothing fixed
It is rented equipment. No holes, no wall vents, no installation — the hose goes out of the door and everything wheels back out afterwards.
Bridge, not a permanent fix
This buys your IT and M&E team time to repair or replace the building system. We are candid about what a portable unit can and cannot hold.
One team since 1985
Our own crew delivers, installs, tests and collects islandwide — behind our 5.0 on Google and Carousell.









Start with these two

Kojima 3 HP Portable Air Conditioner
The workhorse for a comms room with a full rack row — 5500W of cooling on a standard 13A socket. The maker rates it to 70 m², but that is an ordinary room; against a live rack load plan on roughly 3.5 m² per unit.

Kojima 2 HP Portable Aircon
Only 69cm tall and 26cm wide, so it fits a tight aisle or a small comms cupboard — 4200W. Rated to 40 m² in an ordinary room, so figure about 2 m² of server room per unit.
Need something else? Browse all 9 categories →
You never touch the logistics
- 1
Tell us the room size, how many racks, and where the nearest door or window is
- 2
We size it against the rack load, not the floor area — usually two units, more for a full row
- 3
Our crew delivers, positions them on the cold aisle and runs the exhaust hoses out
- 4
When your building cooling is repaired, we collect — nothing left behind, nothing to patch
Two things decide whether this works. First, sizing: a portable unit rated for 70 m² of office will not hold 70 m² of server room — against a live rack load, budget around a twentieth of that, which is why we quote two units where one looks like enough on paper. Second, the exhaust routing, which matters more than most people expect. A portable unit produces heat as well as cold, so if the hot air is not pushed out of the room the temperature will keep climbing. We run the hose out through the door — the door closes onto it — or through an opened window, and we check the room is actually holding before we leave.
Racks getting warm? Tell us the room
Send the room size, the rack count and where the nearest door or window is. We will come back with how many units it needs and how fast we can have them on site.
Same-day quotes · Delivered, installed & tested islandwide · Backup on standby